PDTF Series 70°F to 285°F (20°C to 140°C) Withstands Acceleration to 8G Small Capillary for harsh applications
Gems PDTF Series is a factory set temperature switch for the protection of all types of internal combustion engines, pumps, compressors, gear boxes, hydraulic reservoirs, marine and industrial power plants. Model PDTF will withstand acceleration to 8G. Its compact and rugged construction allows it to be mounted in the toughest OEM applications. The PDTF utilizes a liquid filled capillary to sense temperature changes. The liquid expands as the temperature increases causing the capillary pressure to increase.
Maximum Temperature +55°F (25°C) above set point Switch - Resistive 5 Amp - Inductive 2 Amp @12/24 VDC and 125/250 VAC Setting Tolerance ± 6°F (± 3°C)
Wetted Parts - Housing Zinc plated steel - Capillary Brass Electrical Termination DIN 43650A IP65, Flying leads - IP65 Maximum Probe Pressure 350 psi (25 bar) Approvals CE Deadband 19°F (9°C)Average Weight, Approximate 0.3 lbs. (0.14 kg)